ANALISA EFISIENSI PERFORMA HRSG ( Heat Recovery Steam Generation ) PADA PLTGU

Bambang Setyoko(1*)


(1) 
(*) Corresponding Author

Abstract


Heat Recovery Steam Generator ( HRSG ) is a construction in combine cycle with gas turbine and steam turbine. The steam produced in HRSG with heat from exhaust gas turbine.

In this research we can calculate HRSG efficiency to compare total energy  heat flow for steam produce from feed water and total energy heat flow from exhaust gas turbine.

The result of this calculate research are optimal efficiency 54,04 % with total energy superheated steam heat  flow 132,91 MW, total energy exhaust gas turbine 245,953 MW and minimum efficiency 50,39 % with total energy superheated steam heat flow 124,788 MW, total energy exhaust gas turbine 247,64 MW.

Key words : exhaust gas,steam, heat flow.

 


Full Text:

PDF

Article Metrics

Abstract view : 1790 times
PDF - 1977 times

DOI: https://doi.org/10.26714/traksi.4.2.2006.%25p

Refbacks

  • There are currently no refbacks.


Copyright (c)

Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.


TRAKSI : Majalah Ilmiah Teknik Mesin

ISSN : 1693-3451 (Pinted) e-ISSN : 2579-9738 (Online)

Published by: LP2M Unimus bekerjasama dengan APTI (Asosiasi Profesi Teknik Indonesia)  

 
ADDRESS

Jl. Kasipah No. 12 Semarang

E-mail: traksi@unimus.ac.id Call: 0248445768


Sponsors

Asosiasi Profesi Teknik Indonesia (APTI)

Website: www.apti.or.id