RETROFIT SPEED CONTROL ACTUATOR BOILER FEED PUMP TO IMPROVE STEAM POWER PLANT RELIABILITY
(1) PLN Corporate University
(*) Corresponding Author
Abstract
A Boiler Feed Pump (BFP) is a very important equipment in Steam Power Plants (PLTU), which functions to pump water from the feedwater tank to the boiler drum. If the BFP experiences a disturbance, the PLTU will experience derating or shutdown. For one year, there were repeated disruptions to BFP, causing the plant to experience an unplanned shutdown (Forced Outage/FO). Analysis of disturbance data was carried out to find the root cause of the problem of repeated disturbances in BFP, using the Root Cause Failure Analysis (RCFA) method. RCFA results show that the cause of repeated interference in BFP is a problem with the Speed Control Actuator which uses an Analog Electric Actuator (Motorized) as a Hydraulic Coupling drive. The main disadvantages of the Analog Electric Actuator system are low response speed, easily changing settings, motor protection often fails and the module often hangs. The solution to this problem is to carry out a retrofit to replace the BFP actuator speed control from an Analog Electric Actuator system to a Digital Electro Pneumatic system.. The retrofit was successfully performed on BFP 1A and proved to be able to operate normally without interruption during the period of operation. After a successful retrofit was performed on BFP 1A, the retrofit was also performed on all other BFPs, namely BFP 2B, 2A, and 1B. Overall, retrofit proved to be able to overcome the weaknesses of the Analog Electric Actuator system and improve the reliability of the power plant. Financially, retrofits eliminate corrective maintenance costs of actuator replacement and eliminate potential plant losses due to lost production opportunities.
Keywords
Full Text:
PDFReferences
Arnold, C. L. (2015). FLUID COUPLINGS. CRC Press.
Basu, S., & Debnath, A. K. (2015). Power Plant Instrumentation and Control Handbook : a Guide to Thermal Power Plants. Academyc Press (AP).
Chakraborty, S. K., Manna, N., & Dey, S. (2014). Importance of Three-Elements Boiler Drum Level Control and Its Installation in Power Plant. International Journal of Instrumentation and Control Systems, 4(2), 1–12. https://doi.org/10.5121/ijics.2014.4201
Chen, K. Y., Chen, L. S., Chen, M. C., & Lee, C. L. (2011). Using SVM based method for equipment fault detection in a thermal power plant. Computers in Industry, 62(1), 42–50. https://doi.org/10.1016/j.compind.2010.05.013
Goswami, Y. D., & Kreith, F. (2017). Energy Conversion: Vol. Second Edition (Second Edition). CRC Press.
Mitsui Engineering. (2000a). Boiler Plant Description of System Functions (As Built Drawing). Tripatra Engineering.
Mitsui Engineering. (2000b). Boiler Plant-Unit 1 Function Control Diagram (FCD) for Plant Control System (Automatic Boiler Control) (As Buit Drawing). Tripatra Engineering.
Mobley, R. K. (1999). Root Cause Failure Analysis. Newnes.
Purba, S., Mukdas, E., Krisnamukti, D. B., & Ridwan, I. (2018). SPLN PROGRAMMABLE LOGIC CONTROLLER (PLC) PEMBANGKITAN.
Voith Fluidrive. (1999). Scoop Trimming Coupling - GST50 Installation & Maintenance. In Fluidrive Installation and Maintenance: Vol. I (pp. 1–30). Voith GmbH & Co. KGaA.
Yoshikawa, Shigeru. (2016). Boiler Feed Pump (BFP). Ebara Engineering Review, 251, 11–20.
Article Metrics
Abstract view : 62 timesPDF - 13 times
DOI: https://doi.org/10.26714/traksi.24.1.2024.27-45
Refbacks
- There are currently no refbacks.
Copyright (c) 2024 TRAKSI
This work is licensed under a Creative Commons Attribution 4.0 International License.
TRAKSI : Majalah Ilmiah Teknik Mesin
ISSN : 1693-3451 (Pinted) e-ISSN : 2579-9738 (Online)
Published by: LP2M Unimus bekerjasama dengan APTI (Asosiasi Profesi Teknik Indonesia)
Jl. Kasipah No. 12 Semarang
E-mail: traksi@unimus.ac.id Call: 0248445768
Sponsors
Asosiasi Profesi Teknik Indonesia (APTI)
Website: www.apti.or.id