ANALISA SETTING GROUND FAULT RELAY (GFR) TERHADAP SISTEM PENTANAHAN NETRAL PENYULANG PANDEANLAMPER 06 JTM 20 KV SEMARANG
(1) 
(2) 
(3) 
(*) Corresponding Author
Abstract
The operation of the distribution system has major problems in overcoming interference. In its development, electric power systems increasingly large currents cause electrical interference that may occur the greater. Therefore, they invented a system called neutral grounding.There is no ideal grounding neutral earthing throughout the distribution network Semarang cause neutral grounding resistance value. Neutral resistance values may cause a decrease in current flowing to ground disturbance that affects the sensitivity GFR (Ground Foult Relay) installed. Because of that, necessary to analyze the GFR setting the main feeder neutral earthing systems JTM 20 kV feeders Semarang by
taking samples Pandealamper 06 to determine the condition of setting GFR installed in accordance with the neutral earthing systems.Results of the calculation of the noise current by entering the value of resistance neutral earthing exiting GFR values obtained ideal setting on the feeder Pandeanlamper
06 is not much different from the existing GFR setting value. Values of 0.27 ? neutral earthing (existing) did not significantly influence the sensitivity GFR of the feeder PDL 06.GFR remained
detect interference and work in accordance with the characteristic curve GFR.Based on the analysis, GFR mounted setting was appropriate and able to provide security in Pandeanlamper feeder 06.
Keywords: Neutral Grounding, GFR, Main Feeder
taking samples Pandealamper 06 to determine the condition of setting GFR installed in accordance with the neutral earthing systems.Results of the calculation of the noise current by entering the value of resistance neutral earthing exiting GFR values obtained ideal setting on the feeder Pandeanlamper
06 is not much different from the existing GFR setting value. Values of 0.27 ? neutral earthing (existing) did not significantly influence the sensitivity GFR of the feeder PDL 06.GFR remained
detect interference and work in accordance with the characteristic curve GFR.Based on the analysis, GFR mounted setting was appropriate and able to provide security in Pandeanlamper feeder 06.
Keywords: Neutral Grounding, GFR, Main Feeder
Full Text:
PDFArticle Metrics
Abstract view : 542 timesPDF - 132 times
DOI: https://doi.org/10.26714/me.v9i1.2060
Refbacks
- There are currently no refbacks.
Copyright (c) 2016 MEDIA ELEKTRIKA
Editorial Office of Media Elektrika
Universitas Muhammadiyah Semarang FT-FMIPA Building, 7nd Floor. Phone: 085299398663 |
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.